- Electrical Durability 500,000 operations or more (250 VAC, 3 A, resistance load), 300,000 operations or more (250 VAC, 10 A, resistance load)
- Contact Resistance (m?) 25 or less
- Open thermal current (A) 10(EN60947-5-1)
- Shock Resistance (Mis-operation) 300m/s2
- Rated Impulse Withstand Voltage (kV) Between homopolar terminals: 2.5 Between different polar terminals: 4 Between each terminal and non-charged metal part: 6
- Allowable Operating Speed 1 to 500 mm / s (D4N-1120)
- Vibration Resistance (Mis-operation) 10-55Hz 0.75mm single amplitude
- Built-in switch 2NC (slow action)
- Operation Ambient Temperature (?) -30 to +70 (but no freezing)
- Protection Class IP67(EN60947-5-1)
- Rated Frequency (Hz) 50/60
- Insulation Resistance (M?) over 100
- Shock Resistance (Endurance) 1000m/s2
- Allowable Operation Frequency Up to 30 times / min
- Electric Shock Protection Class Class II (double insulation)
- Pollution Degree (Environment to Use) Pollution degree 3 (EN60947-5-1)
- Type of Actuator Roller plunger type
- Conditional Short-Circuit Current 100A(EN60947-5-1)
- Conduit mouth size G1 / 2 (1 conduit type)
- Mechanical Durability 15 million times or more
- Rated Insulation Voltage (V) (Ui)300